ref: e59ffed426f628794d4669f152eff9a6239b99db
dir: /man/10/plan9.ini/
.TH PLAN9.INI 10.6 .SH NAME plan9.ini \- configuration file for PCs .SH SYNOPSIS .I none .SH DESCRIPTION When booting Inferno on a PC, the Plan 9 bootstrap programs are used, hence the references to Plan 9 below. The DOS program .IR 9load (10.8) first reads a DOS file containing configuration information from the boot disk. This file, .BR plan9.ini , looks like a shell script containing lines of the form .PP .EX name=\f2value\fP .EE .LP each of which defines a kernel or device parameter. .PP For devices, the generic format of .I value is .PP .EX type=TYPE [port=N] [irq=N] [mem=N] [size=N] [dma=N] [ea=N] .EE .LP specifying the controller type, the base I/O port of the interface, its interrupt level, the physical starting address of any mapped memory, the length in bytes of that memory, the DMA channel, and for Ethernets an override of the physical network address. Not all elements are relevant to all devices; the relevant values and their defaults are defined below in the description of each device. .PP The file is used by .B 9load and the kernel to configure the hardware available. The information it contains is also passed to the boot process, and subsequently other programs, as environment variables (see also .B osinit.dis in .IR root (3)). However, values whose names begin with an asterisk .B * are used by the kernel and are not converted into environment variables. .PP The following sections describe how variables are used. .SS \fLetherX=value\fP This defines an Ethernet interface. .IR X , a unique monotonically increasing number beginning at 0, identifies an Ethernet card to be probed at system boot. Probing stops when a card is found or there is no line for .BR etherX+1 . After probing as directed by the .BI ether X lines, any remaining ethernet cards that can be automatically detected are added. Almost all cards can be automatically detected. For debugging purposes, automatic probing can be disabled by specifying the line .BR *noetherprobe= . This automatic probing is only done by the kernel, not by .IR 9load (10.8). Thus, if you want to load a kernel over the ethernet, you need to specify an .B ether0 line so that .I 9load can find the ethernet card, even if the kernel would have automatically detected it. .PP Some cards are software configurable and do not require all options. Unspecified options default to the factory defaults. .PP Known types are .TP .B ne2000 Not software configurable. 16-bit card. Defaults are .EX port=0x300 irq=2 mem=0x04000 size=0x4000 .EE The option (no value) .B nodummyrr is needed on some (near) clones to turn off a dummy remote read in the driver. .TP .B amd79c970 The AMD PCnet PCI Ethernet Adapter (AM79C970). (This is the ethernet adapter used by VMware.) Completely configurable, no options need be given. .TP .B wd8003 Includes WD8013 and SMC Elite and Elite Ultra cards. There are varying degrees of software configurability. Cards may be in either 8-bit or 16-bit slots. Defaults are .EX port=0x280 irq=3 mem=0xD0000 size=0x2000 .EE BUG: On many machines only the 16 bit card works. .TP .B elnk3 The 3COM Etherlink III series of cards including the 5x9, 59x, and 905 and 905B. Completely configurable, no options need be given. The media may be specified by setting .B media= to the value .BR 10BaseT , .BR 10Base2 , .BR 100BaseTX , .BR 100BaseFX , .BR aui , and .BR mii . If you need to force full duplex, because for example the Ethernet switch does not negotiate correctly, just name the word (no value) .B fullduplex or .BR 100BASE-TXFD . Similarly, to force 100Mbit operation, specify .BR force100 . Port 0x110 is used for the little ISA configuration dance. .TP .B 3c589 The 3COM 3C589 series PCMCIA cards, including the 3C562 and the 589E. There is no support for the modem on the 3C562. Completely configurable, no options need be given. Defaults are .EX port=0x240 irq=10 .EE The media may be specified as .B media=10BaseT or .BR media=10Base2 . .TP .B ec2t The Linksys Combo PCMCIA EthernetCard (EC2T), EtherFast 10/100 PCMCIA cards (PCMPC100) and integrated controllers (PCM100), the Netgear FA410TX 10/100 PCMCIA card and the Accton EtherPair-PCMCIA (EN2216). Completely configurable, no options need be given. Defaults are .EX port=0x300 irq=9 .EE These cards are NE2000 clones. Other NE2000 compatible PCMCIA cards may be tried with the option .EX id=string .EE where .B string is a unique identifier string contained in the attribute memory of the card (see .IR pcmcia (8)); unlike most options in .BR plan9.ini , this string is case-sensitive. The option .B dummyrr=[01] can be used to turn off (0) or on (1) a dummy remote read in the driver in such cases, depending on how NE2000 compatible they are. .TP .B i82557 Cards using the Intel 8255[789] Fast Ethernet PCI Bus LAN Controller such as the Intel EtherExpress PRO/100B. Completely configurable, no options need be given. If you need to force the media, specify one of the options (no value) .BR 10BASE-T , .BR 10BASE-2 , .BR 10BASE-5 , .BR 100BASE-TX , .BR 10BASE-TFD , .BR 100BASE-TXFD , .BR 100BASE-T4 , .BR 100BASE-FX , or .BR 100BASE-FXFD . .TP .B 2114x Cards using the Digital Equipment (now Intel) 2114x PCI Fast Ethernet Adapter Controller, for example the Netgear FA310. Completely configurable, no options need be given. Media can be specified the same was as for the .BR i82557 . Some cards using the .B PNIC and .B PNIC2 near-clone chips may also work. .\" .TP .\" .B ga620 .\" Netgear GA620 and GA620T Gigabit Ethernet cards, .\" and other cards using the Alteon Acenic chip such as the .\" Alteon Acenic fiber and copper cards, .\" the DEC DEGPA-SA and the SGI Acenic. .\" Completely configurable. .TP .B wavelan Lucent Wavelan (Orinoco) IEEE 802.11b and compatible PCMCIA cards. Compatible cards include the Dell TrueMobile 1150 and the Linksys Instant Wireless Network PC Card. Port and IRQ defaults are 0x180 and 3 respectively. These cards take a number of unique options to aid in identifying the card correctly on the 802.11b network. The network may be .I "ad hoc" or .I managed (i.e. use an access point): .EX mode=[adhoc, managed] .EE and defaults to .IR managed . The 802.11b network to attach to .RI ( managed mode) or identify as .RI ( "ad hoc" mode), is specified by .EX essid=string .EE and defaults to a null string. The card station name is given by .EX station=string .EE and defaults to .IR "Plan 9 STA" . The channel to use is given by .EX channel=number .EE where .I number lies in the range 1 to 16 inclusive; the channel is normally negotiated automatically. If the card is capable of encryption, the following options may be used: .EX crypt=[off, on] .EE and defaults to .IR on . .EX key\fIN\fP=string .EE sets the encryption key .I n (where .I n is in the range 1 to 4 inclusive) to .IR string ; this will also set the transmit key to .I n (see below). .EX txkey=number .EE sets the transmit key to use to be .I number in the range 1 to 4 inclusive. If it is desired to exclude or include unencrypted packets .EX clear=[off, on] .EE configures reception and defaults to inclusion. The defaults are intended to match the common case of a managed network with encryption and a typical entry would only require, for example .EX essid=left-armpit key2=fishcalledraawaru .EE if the port and IRQ defaults are used. These options may be set after boot by writing to the device's .I ctl file using a space as the separator between option and value, e.g. .EX echo 'key2 fishcalledraawaru' > /net/ether0/0/ctl .EE .TP .B wavelanpci PCI ethernet adapters that use the same Wavelan programming interface. Currently the only tested cards are those based on the Intersil Prism 2.5 chipset. .TP .B 83815 National Semiconductor DP83815-based adapters, notably the Netgear FA311, Netgear FA312, and various SiS built-in controllers such as the SiS900. On the SiS controllers, the ethernet address is not detected properly; specify it with an .B ea= attribute. .\" .TP .\" .B 83820 .\" National Semiconductor DP83820-based gigabit ethernet adapters, notably .\" the D-Link DGE-500T. .TP .B rtl8139 The Realtek 8139. .TP .B 82543gc The Intel RS-82543GC gigabit ethernet controller, as found on the Intel PRO/1000[FT] server adapter. The older non-[FT] cards based on the 82542 (LSI L2A1157) chip are not supported, although support would probably be easy to add. .TP .B smc91cxx SMC 91cXX chip-based PCMCIA adapters, notably the SMC EtherEZ card. .TP .B sink A .B /dev/null for ethernet packets \(em the interface discards sent packets and never receives any. This is used to provide a test bed for some experimental ethernet bridging software. .SS \fLusbX=type=uhci port=xxx irq=xxx\fP This specifies the settings for a USB UHCI controller. Like the ethernet controllers, USB controllers are autodetected after scanning for the ones listed in .IR plan9.ini . Thus, most systems will not need a .B usbX line. Also like the ethernet controllers, USB autoprobing can be disabled by specifying the line .BR *nousbprobe= . .SS \fLscsiX=value\fP This defines a SCSI interface which cannot be automatically detected by the kernel. .PP Known types are .TP .B aha1542 The Adaptec 154x series of controllers (and clones). Almost completely configurable, only the .EX port=0x300 .EE option need be given. .PP NCR/Symbios/LSI Logic 53c8xx-based adapters and Mylex MultiMaster (Buslogic BT-*) adapters are automatically detected and need no entries. .PP By default, the NCR 53c8xx driver searches for up to 32 controllers. This can be changed by setting the variable .BR *maxsd53c8xx . .PP By default the Mylex driver resets SCSI cards by using both the hard reset and SCSI bus reset flags in the driver interface. If a variable .BR *noscsireset is defined, the SCSI bus reset flag is omitted. .SS Uarts Plan 9 automatically configures COM1 and COM2, if found, as .B eia0 (port 0x3F8, IRQ4) and .B eia1 (port 0x2F8, IRQ3) respectively. These devices can be disabled by adding a line: .EX eia\fIX\fP=disabled .EE This is typically done in order to reuse the IRQ for another device. .PP The system used to support various serial concentrators, including the TTC 8 serial line card and various models in the Star Gate Avanstar series of intelligent serial boards. These are no longer supported; the much simpler Perle PCI-Fast4, PCI-Fast8, and PCI-Fast16 controllers have taken their places. These latter cards are automatically detected and need no configuration lines. .PP The line .B serial=type=com can be used to specify settings for a PCMCIA modem. .SS \fLmouseport=value\fP This specifies where the mouse is attached. .I Value can be .TP .B ps2 the PS2 mouse/keyboard port. The BIOS setup procedure should be used to configure the machine appropriately. .TP .B ps2intellimouse an Intellimouse on the PS2 port. .TP .B 0 for COM1 .TP .B 1 for COM2 .SS \fLmodemport=value\fP Picks the UART line to call out on. This is used when connecting to a file server over an async line. .I Value is the number of the port. .SS \fLpccard0=disabled\fP Disable probing for and automatic configuration of PC card controllers. .SS \fLpcmciaX=type=XXX irq=value\fP If the default IRQ for the PCMCIA is correct, this entry can be omitted. The value of .B type is ignored. .SS \fLpcmcia0=disabled\fP Disable probing for and automatic configuration of PCMCIA controllers. .SS \fLconsole=value params\fP This is used to specify the console device. The default value is .BR cga ; a number .B 0 or .B 1 specifies .I COM1 or .I COM2 respectively. A serial console is initially configured with the .IR eia (3) configuration string .B b9600 .B l8 .B pn .BR s1 , specifying 9600 baud, 8 bit bytes, no parity, and one stop bit. If .I params is given, it will be used to further configure the uart. Notice that there is no .B = sign in the .I params syntax. For example, .EX console=0 b19200 po .EE would use COM1 at 19,200 baud with odd parity. .SS \fLbootfile=value\fP This is used to direct the actions of .IR 9load (10.8) by naming the device and file from which to load the kernel. .SS \fLpartition=value\fP This defines the partition table .IR 9load (10.8) will examine to find disk partitioning information. By default, a partition table in a Plan 9 partition is consulted; if no such table is found, an old-Plan 9 partition table on the next-to-last or last sector of the disk is consulted. A value of .B new consults only the first table, .B old only the second. .SS \fL*maxmem=value\fP This defines the maximum physical address that the system will scan when sizing memory. By default the operating system will scan up to 768 megabytes, but setting .B *maxmem will limit the scan. If the system has more than 768 megabytes, you must set .B *maxmem for the kernel to find it. .B *maxmem must be less than 1.75 gigabytes. .SS \fL*kernelpercent=value\fP This defines what percentage of available memory is reserved for the kernel allocation pool. The remainder is left for user processes. The default .I value is .B 30 on CPU servers, .B 60 on terminals with less than 16MB of memory, and .B 40 on terminals with memories of 16MB or more. Terminals use more kernel memory because .IR draw (3) maintains its graphic images in kernel memory. This deprecated option is rarely necessary in newer kernels. .SS \fL*nomce=value\fP If machine check exceptions are supported by the processor, then they are enabled by default. Setting this variable to .B 1 causes them to be disabled even when available. .SS \fL*nomp=\fP A multiprocessor machine will enable all processors by default. Setting .B *nomp restricts the kernel to starting only one processor and using the traditional interrupt controller. .SS \fL*ncpu=value\fP Setting .B *ncpu restricts the kernel to starting at most .I value processors. .SS \fL*pcimaxbno=value\fP This puts a limit on the maximum bus number probed on a PCI bus (default 255). For example, a .I value of 1 should suffice on a 'standard' motherboard with an AGP slot. This, and .B *pcimaxdno below are rarely used and only on troublesome or suspect hardware. .SS \fL*pcimaxdno=value\fP This puts a limit on the maximum device number probed on a PCI bus (default 31). .SS \fL*nopcirouting=\fP Disable pci routing during boot. May solve interrupt routing problems on certain machines. .\" .SS \fL*nobios=\fP .\" what does this do? something with pci .SS \fLioexclude=value\fP Specifies a list of ranges I/O ports to exclude from use by drivers. Ranges are inclusive on both ends and separated by commas. For example: .EX ioexclude=0x330-0x337,0x430-0x43F .EE .SS \fLapm0=\fP This enables the ``advanced power management'' interface as described in .IR apm (3). ....and .....IR apm (8). The main feature of the interface is the ability to watch battery life. ....battery life (see .....IR stats (8)). It is not on by default because it causes problems on some laptops. .SS \fLmonitor=value\fP .SS \fLvgasize=value\fP These are used not by the kernel but by system initialisation. .SS \fL*dpms=value\fP This is used to specify the screen blanking behavior of the MGA4xx video driver. Values are .BR standby , .BR suspend , and .BR off . The first two specify differing levels of power saving; the third turns the monitor off completely. .SS \fLnvr=value\fP This is used by a file server kernel to locate a file holding information to configure the file system. The file cannot live on a SCSI disk. The default is .B fd!0!plan9.nvr (sic), unless .B bootfile is set, in which case it is .B plan9.nvr on the same disk as .BR bootfile . The syntax is either .BI fd! unit ! name or .BI hd! unit ! name where .I unit is the numeric unit id. This variant syntax is a vestige of the file server kernel's origins. .SS \fLaudioX=value\fP This defines a sound interface. .PP Known types are .TP .B sb16 Sound Blaster 16. .TP .B ess1688 A Sound Blaster clone. .PP The DMA channel may be any of 5, 6, or 7. The defaults are .EX port=0x220 irq=7 dma=5 .EE .SS \fLfs=a.b.c.d\fP .SS \fLauth=a.b.c.d\fP These specify the IP address of the file and authentication server to use when mounting a network-provided root file system. They are used only if the addresses cannot be determined via DHCP. .SH Multiple Configurations .PP A .B plan9.ini file may contain multiple configurations, each within a block beginning with a line .EX [tag] .EE A special block with the tag .B menu gives a list of blocks from which the user may interactively select the contents of .BR plan9.ini . There may also be multiple blocks with the tag .B common which will be included in all selections; if any lines appear in .B plan9.ini before the first block, they are treated as a .B common block. .LP Within the .B menu block the following configuration lines are allowed: .SS \fLmenuitem=tag[, description] The block identified by .B tag will appear in the presented menu. The menu entry will consist of the .B tag unless the optional .B description is given. .SS \fLmenudefault=tag[, timeout] Identifies a default block to be given in the menu selection prompt. If the optional .B timeout is given (in seconds), the default block will be selected if there is no user input within the timeout period. .SS \fLmenuconsole=value[, baud] Selects a serial console upon which to present the menu as no .B console or .B baud configuration information will have been processed yet (the .B plan9.ini contents are still to be decided...). .LP In response to the menu being printed, the user is prompted to select a menu item from the list. If the numeric response is followed by a .BR p , the selected configuration is printed and the menu presented again. .LP The line .EX menuitem=tag .EE is prefixed to the selected configuration as an aid to user-level initialization scripts. .SH EXAMPLES .PP A representative .BR plan9.ini : .IP .EX % cat /n/c:/plan9.ini ether0=type=3C509 mouseport=ps2 modemport=1 serial0=type=generic port=0x3E8 irq=5 monitor=445x vgasize=1600x1200x8 % .EE .PP Minimum CONFIG.SYS and AUTOEXEC.BAT files to use COM2 as a console: .IP .EX % cat /n/c:/config.sys SHELL=COMMAND.COM COM2 /P % cat /n/c:/autoexec.bat @ECHO OFF PROMPT $p$g PATH C:\eDOS;C:\eBIN mode com2:96,n,8,1,p SET TEMP=C:\eTMP % .EE .PP Simple .B plan9.ini with multiple configurations: .IP .EX [menu] menuitem=vga, Plan 9 with VGA menuitem=novga, Plan 9 no automatic VGA menudefault=vga [vga] monitor=multisync135 vgasize=1024x768x8 [novga] [common] ether0=type=i82557 audio0=type=sb16 port=0x220 irq=5 dma=1 .EE .PP With this, the following menu will be presented on boot: .IP .EX Plan 9 Startup Menu: ==================== 1. Plan 9 with VGA 2. Plan 9 no automatic VGA Selection[default==1]: .EE .PP Selecting item 1 generates the following .B plan9.ini to be used by the remainder of the bootstrap process: .IP .EX menuitem=vga monitor=multisync135 vgasize=1024x768x8 ether0=type=i82557 audio0=type=sb16 port=0x220 irq=5 dma=1 .EE .PP and selecting item 2: .IP .EX menuitem=novga ether0=type=i82557 audio0=type=sb16 port=0x220 irq=5 dma=1 .EE .SH "SEE ALSO" .IR root (3), .IR 9load (10.8) .SH BUGS Being able to set the console device to other than a display is marginally useful on file servers; MS-DOS and the programs which run under it are so tightly bound to the display that it is necessary to have a display if any setup or reconfiguration programs need to be run. Also, the delay before any messages appear at boot time is disconcerting, as any error messages from the BIOS are lost. .PP This idea is at best an interesting experiment that needs another iteration.